TECHNICIAL SPECIFICATION
Click to download:MEWOI-DRKH2-(300-2000A) (AC/DC) 40.5mm Open-loop Hall current Sensor Specification
Model Number | MEWOI-DRKH2-(300-2000A)(AC/DC) |
Jaw Size | 40.5mm |
Rated input Current (IPN) | 300 | 400 | 600 | 800 | 1000 | 2000 | A |
Primary Current Measure range(IP) | 0~±600 | 0~±800 | 0~±1200 | 0~±1600 | 0~±2000 | 0~±3000 | A |
Rated output voltage of secondary side | 4or5±1% | V |
Power Supply Voltage (VCC) | DC ±12V- ±15V (±5%) | V |
Current consumption | VCC=+15V 25 | mA |
Galvanic isolation (Vd) | 2.5KV /50Hz/1min |
|
Linearity (εL) | <1 | %FS |
Accuracy X | TA =25℃ ±1 | % |
Offset Voltage V0 | TA =25℃ ±25 | mV |
Hysteresis offset Current IOM | ≤±20 | mV |
Offset Voltage drift VOT | IP=0 TA =-25~+85℃ <±1 | mV /℃ |
Response time Tr | <3 | μs |
Operating temperature TA | -25~+85 | ℃ |
Storage temperature TS | -40~+100 | ℃ |
Frequency bandwidth(-3dB) | DC-20 | KHZ |
Load resistance RL | ≥10k | Ω |
1:+ (VCC ) 2:-(NC)3:M (Vout) 4:G(GND) 5: OFS:Zero adjustment 6: GIN: Amplitude regulation
Matters needing attention:
The wrong connection may cause sensor damage. After the sensor is energized, the same phase voltage is measured at the output when the current wire cross the sensor center according the direction arrow indicating label. The output range of the sensor can be adjusted according to the user's needs. During the installation process, before closing the jaw, make sure the connecting interface is aligned, not forcibly closed
|
Hall Current Sensor Selection Guide
Model Number | Range | Diameter | Output | Power Supply |
MEWOI-DRB1 | 50,100,200,300A | 20mm(Close Loop) | 50,100,100,150mA | DC ±12V~±15V (±5%) |
MEWOI-DRK1D | 50,100,200,300,400,500A(AC/DC) | 21mm(Open Loop) | 2.5±1.25V ( ±1%) | DC +5V (±5%) |
MEWOI-DRK1 | 50,100,200,300,400,500A(AC/DC) | 21mm(Open Loop) | 4or5,4-20 mA,0-20 mA±1% | DC ±12V~±15V (±5%) |
MEWOI-DRK1AC | 50,100,200,300,400,500A(AC) | 21mm(Open Loop) | 4or5,4-20 mA,0-20 mA±1% | DC ±12V~±15V (±5%) |
MEWOI DRK3D | 50,100,200,300,400,500A(AC/DC) | 10*20mm(Open Loop) | 2.5V±1.25V ±1% | DC +5V (±5%) |
MEWOI DRK3 | 50,100,200,300,400,500A(AC/DC) | 10*20mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) |
MEWOI DRK5 | 300,500,600,800,1000,1500A(AC/DC) | 37*42.5mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) |
MEWOI DRKH1 | 50,100,200,300,400,500A(AC/DC) | 21mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) |
MEWOI DRKH2 | 300,400,600,800,1000,2000A(AC/DC) | 40.5mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) |
MEWOI DRKH4 | 600,800,1000,2000,2500,3000A(AC/DC) | 80mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) |
MEWOI DRKH5 | 600,1000,2000,3000,5000A(AC/DC) | 42*400mm(Open Loop) | 4±1% | DC ±12V- ±15V (±5%) |