MEWOI-CT23,CT55,CT58,CT88,Series Split Current Transformer

Electricity Testing Instruments manufacturer, Support OEM/ODM, your testing specialist

  • Main Features:: 1.Small size, low cost 2.High secondary turns 3.Secure locking hinge
  • Model No.:: MEWOI-CT23,CT55,CT58,CT88,CT410,CT610,CT816
  • Name:: MEWOI-CT23,CT55,CT58,CT88,CT410,CT610,CT816 Split Core Current Sensor/Transformer

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

MEWOI-CT23,CT55,CT58,CT88,CT410,CT610,CT812,CT816  Split Core Current Transformers

INTRODUCTION

Click to download:  MEWOI-CT23,CT55,CT58,CT88,CT410,CT610,CT812,CT816 Split Core Current Sensor Specification

MEWOI-CT23,CT55,CT58,CT88,CT410,CT610,CT812,CT816 series of split type current transformers are mainly used in industrial urban network, agricultural network transformation project, easy installation, no need to disassemble any cable or bus-bar circuit, and support electrified operation, not affect the normal power consumption of users, save a lot of manpower and material resources for the user transformation project, and improve the efficiency of transformation. This series current transformer can be used in conjunction with relay protection, measurement and metering devices. At present, it is widely used in transformation projects such as semiconductor industry.

SPECIFICATION

Model NumberMEWOI-CT23,CT55,CT58,CT88,CT410,CT610,CT812,CT816
Apply toGB28040 and IEC68169
Rated Voltage0.66/0.72KVrms
Primary Current input
100-5000Arms
Secondary Output5Arms/1Arms
Insulaiton Strength2KVac/min
Insulation ResistanceDC500V/100MΩ
Working frequency50-400Hz
Operating Temperature-25℃to 50℃.
Storage Temperature-30℃to 70℃.
Matters needing attention
  • When the transformer is in primary current, the second winding must not open circuit, otherwise the two will form high pressure, which will cause harm to the product performance and staff. 

  • The repeated voltage withstand test of the transformer should be carried out at 80% of the rated voltage.

SELECTION GUIDE

Output:5A

Model
Rated Input/Output(A)Accuracy ClassLoading(VA)FrequencyInsulation Strength
CT23
100/51≦1.0

50/60HZ

 ≦3KV

150/5
1≦1.0
200/50.5≦1.5
250/50.5≦1.5
300/50.5≦2.5
400/50.5≦2.5
CT58250/51
≦1.5

50/60HZ

 ≦3KV

300/5
1≦1.5
400/50.5≦1.5
500/50.5≦2.5
600/50.5≦2.5
750/50.5≦2.5
800/50.5≦2.5
1000/50.5≦5
CT88250/51
≦1.5

   50/60HZ

 ≦3KV

300/5
1≦1.5
400/50.5≦1.5
500/50.5≦2.5
600/50.5≦2.5
750/50.5≦2.5
800/50.5≦2.5
1000/50.5≦5
CT812250/51
≦1.5

   50/60HZ

 ≦3KV

300/5
1≦1.5
400/50.5≦1.5
500/50.5≦2.5
600/50.5≦2.5
750/50.5≦2.5
800/50.5≦2.5
1000/50.5≦5
CT410250/51
≦1.5

   50/60HZ

 ≦3KV

300/5
1≦1.5
400/50.5≦1.5
500/50.5≦2.5
600/50.5≦2.5
750/50.5≦2.5
800/50.5≦2.5
1000/50.5≦5
CT610250/51
≦1.5

   50/60HZ

 ≦3KV

300/5
1≦1.5
400/50.5≦1.5
500/50.5≦2.5
600/50.5≦2.5
750/50.5≦2.5
800/50.5≦2.5
1000/50.5≦5
CT812250/51
≦1.5

   50/60HZ

 ≦3KV

300/5
1≦1.5
400/50.5≦1.5
500/50.5≦2.5
600/50.5≦2.5
750/50.5≦2.5
800/50.5≦2.5
1000/50.5≦5
CT8161000/51
≦10

   50/60HZ

 ≦3KV

1500/5
1≦15
2000/50.5≦15
2500/50.5≦15
3000/50.5≦15
4000/50.5≦15
5000/50.5≦15

MEWOI-clamp meter|earth ground resistance tester|pinza|接地电阻|curent sensor probe|电流传感器


Telephone
E-mail
After Sales
QQ