MEWOI140B-35-40mm,AC 0.0A~600A,Turn Ratio 1:4000 Clamp on Leakage current sensor meter,Current Transducer

Professional OEM/ODM Manufacturer for electrical testing instruments,your testing specialist

  • Main Features:: 1,AC current detection 2, Range: 0.0A~600A 3,clamp size:35mm×40mm
  • Model No.:: MEWOI140B
  • Name:: MEWOI140B-35*40mm,AC 0.0A~600A,Turn Ratio 1:4000 Clamp on Leakage current sensor meter

MEWOI140B-Clamp AC 0.1A~600A Current sensor probe/meter/tester/pinza/alicate amperímetro

Contact Us for Quotation

Email1:billy.sz.china@gmail.com

Whatsapp: +8618620373879
Click to: Products MapEmail2: mewoi@mewoi.com

Ⅰ.INTRODUCTION

Click to download: MEWOI140,140B,140C Leakage Clamp Current Sensor User Manual

MEWOI140B Clamp Current Sensor, with the characteristics of small size, high accuracy, good stability and strong anti-interference ability.It can be connected with high precision digital multi-meter and data recorder..Widely applied in electricity, communication, meteorology, industrial and mining enterprises.

MEWOI140B  Clamp Current Sensor adopt up-to-date CT technology, can almost shield the influence from external magnetic field, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement. It suitable for big current test.

Technical Specifications

Function

Measurement of AC current, leakage current, high order harmonic

 current, phase, power energy, power, power factor

Test mode

Clamp CT

Clamp Size

35mm×40mm

Range

0.0~600A  AC

Resolution

0.1A AC

Accuracy

±1.0%FS(50Hz/60Hz; 23°C±2°C, below 70%RH, keep the wire be in the center of clamp)

Coils Turn

1:4000

Phase Error

≤3°(50Hz/60Hz; 23°C±2°C)

Reference Load

RL:0~300mA≤500Ω; 0~3A≤50Ω; 0~30A≤5Ω; 0~300A≤0.5Ω

Output Mode

Current induction output

Output Interface

φ3.5mm audio plug or Choose two root welding thread or standard multi-meter pen plugs

Output Wire Length

2m

Electric Field Interference

About 10mA when the external electric field 100A, 10mm nearby

Measured Wire Position

Approximately in the geometric center of the clamp

Current Frequency

45H-60Hz(when measuring big current)

Frequency Characteristics

10Hz~100kHz

Line Voltage 

Below AC 600V

Dimension

120mm×70mm×33mm

Weight

190g

Working Environment

-20°C-50°C; below 80%rh

Storage Environment

-10°C-60°C; below 70%rh

Insulation Strength

AC3700V/rms (between core and shell)

Safety Rules

IEC1010-1, IEC1010-2-032, Pollution degree 2, CAT III (600V)

Ⅱ.APPLICATION

MEWOI140B 英文application.png

SELECTION GUIDE 1

Clamp on Current Sensor Probe For Terminals Such Mulitimeter&Oscilloscope 

Click "Blue" marked Model No. to View the Spec

ModelRangeResolution
Clamp SizePower Supply&output
Hall effectCurrent induction output,Direct Coil tap Others
MEWOI107BEMEWOI107BE_副本.8.jpg

0mA~60A

 (AC/DC)

1mA  Φ7mm    Power Supply: 9VDC, Output:10mV/A,100mV/A, Accuracy 3%
Suitable for small spaces AC / DC leakage current, low current test.
MEWOI108MEWOI108-1_副本_副本.80.jpg0.0mA~30A (AC)

0.1mA,

Accuracy 0.5% 

Φ8 mm 

Suitable for small spaces AC leakage current, harmonic, phase, Power test
MEWOI130MEWOI130.80.jpg0.000mA~60A (AC), 0.001mA,Accuracy: 1%25*30mm 

Double shielding, anti-jamming capability,suitable for leakage current,small current test.
MEWOI130EMEWOI130.80.jpg0.00A~10A (DC),  0.01A    25*30mm Power supply: 9VDC, output:0~2.5mV/10mA,Accuracy: 3%,Turns ratio:1:800 

Double shielding, anti-jamming capability,suitable for small DC current test.
MEWOI130E2MEWOI130.80.jpg

0.0mA

~100mA

 (DC), 

0.1mA      25*30mm Power supply: 9VDC, output:0~2.5mV/1mA,Accuracy: 3%,Turns ratio:1:800 

Double shielding, anti-jamming capability,suitable for DC leakage current test.
MEWOI130BEMEWOI130BE.0_副本80.jpg0mA~60A (AC/DC)    1mA25*30mmPower supply: 9VDC, output:10mV/A,100mV/A,Accuracy: 2%  
suitable for AC/DC current test
MEWOI135BEMEWOI135BE.80.jpg0.0A~1000A (AC/DC)    0.1A30*35mm     Power supply: 9VDC, output:1mV/1A,Accuracy: 2%   
suitable for AC/DC current test
MEWOI140MEWOI140_副本80.jpg

0.00mA

~300A

 (AC)  

Turn Ratio

1:2400

0.01mA,Accuracy: 1%   35*40mm  

Single shielding, suitable for leakage current, small current test
MEWOI140BMEWOI140_副本80.jpg

0.0A~600A (AC)


Turn Ratio

1:4000


0.1A,

Accuracy: 1% 

35*40mm 

suitable for big current test
MEWOI140CMEWOI140B_副本80.jpg

0.0mA

~100A

 (AC)

Turn Ratio

1:2000

0.1mA,

Accuracy: 1%

35*40mm

suitable for current, harmonic, phase, Power test
MEWOI168MEWOI068-1_副本80.jpg

0.00mA

~1000A 

(AC)       

0.01mA,

Accuracy: 1%       

Φ68mm 

Double shielding, anti-jamming capability,suitable for leakage current, current test
MEWOI168BMEWOI168.80.jpg0.0A~2000A (AC)

0.1A,

Accuracy: 2%

Φ68mm 

suitable for current, harmonic, phase, Power test
MEWOI168CMEWOI168.80.jpg0.00A~1000A (AC)

1mA,

Accuracy: 2% 

Φ68mm

suitable for current, harmonic, phase, Power test
MEWOI168BEMEWOI168BE-80.jpg

0.0A~2000A (DC),

0.0A~1000A(AC)

0.1mAΦ68mm

Power supply: 9VDC,

output:1mV/1A, 

Accuracy: 2%


suitable for AC/DC big current test

SELECTION GUIDE 2

Flexible Coil Current Sensor Probe For Terminals Such as Mulitimeter&Oscilloscope 

Click "Blue" marked Model No. to View the Spec

Model
Flexible CTRangeResolutionCoil lengthDiameterApplication
MEWOI200GMEWOI200G-80.jpgΦ100 mm

AC

10mA~10000A~more

10mA315mm (Can be customized)φ7.5mm(suitable for narrow and cable-intensive places)



Measure AC big current, high harmonic currents, complex Waveforms current,   inrush transient current.


Suitable for measuring the size of a large or irregularly shaped conductor current

MEWOI300GMEWOI300G-80.jpgΦ200 mm

AC

10mA~10000A~more

10mA630mm (Can be customized)φ7.5mm(suitable for narrow and cable-intensive places)
MEWOI400GMEWOI400G-80.jpgΦ300 mm

AC

10mA~10000A~more

10mA1000mm (Can be customized)φ7.5mm(suitable for narrow and cable-intensive places)

Technical Specifications

Function

Measurement of AC current, leakage current, high order harmonic

 current, phase, power energy, power, power factor

Test mode

Clamp CT

Clamp Size

35mm×40mm

Range

0.0~600A  AC

Resolution

0.1A AC

Accuracy

±1.0%FS(50Hz/60Hz; 23°C±2°C, below 70%RH, keep the wire be in the center of clamp)

Coils Turn

1:4000

Phase Error

≤3°(50Hz/60Hz; 23°C±2°C)

Reference Load

RL:0~300mA≤500Ω; 0~3A≤50Ω; 0~30A≤5Ω; 0~300A≤0.5Ω

Output Mode

Current induction output

Output Interface

φ3.5mm audio plug or Choose two root welding thread or standard multi-meter pen plugs

Output Wire Length

2m

Electric Field Interference

About 10mA when the external electric field 100A, 10mm nearby

Measured Wire Position

Approximately in the geometric center of the clamp

Current Frequency

45H-60Hz(when measuring big current)

Frequency Characteristics

10Hz~100kHz

Line Voltage 

Below AC 600V

Dimension

120mm×70mm×33mm

Weight

190g

Working Environment

-20°C-50°C; below 80%rh

Storage Environment

-10°C-60°C; below 70%rh

Insulation Strength

AC3700V/rms (between core and shell)

Safety Rules

IEC1010-1, IEC1010-2-032, Pollution degree 2, CAT III (600V)

1*clamp meter,User Manual

Telephone
E-mail
After Sales
QQ