MEWOI3200-0.01-1500Ω/0.00mA-40.0A Alicate Terrômetro Alicate testador da resistência de aterramento,Medidores de resistência de terra

OEM/ODM Instruments Manufacturer

  • Principais características:: 1,Gama de resistência:0.01-1500Ω,2,Gama de Corrente:0.00mA-40.0A,3,Totó:99sets,4,Dimensão pinça:65mm×32mm
  • Número de modelo.:: MEWOI3200
  • Name:: MEWOI3200-0.01-1500Ω/0.00mA-40.0A Alicate Terrômetro Alicate testador da resistência de aterramento,Medidores de resistência de terra

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879
Click To: Products Guide Map


MEWOI3200-Alicate Terrômetro,Alicate testador da resistência de aterramento,Testadores de Resistência à Terra de Grampos,Pinça amperimétrica de resistência de Terra,Testadores De Aterramento,Medidores de resistência de terra

INTRODUCTION

Click to download: MEWOI3200 Alicate-Terrômetro Manual

Click to download:  MEWOI3200 Alicate-Terrômetro Color Page

Click to download: Alicate-Terrômetro Field Application Guide

MEWOI-clamp meter|earth ground resistance tester|pinza|接地电阻|curent sensor probe|电流传感器

Introdução

Alicate Terrômetro,Medições de resistência do aterramento de seleção automática de 0,01 Ohm a 1500 Ohm com resolução de 0,01 Ohm

Variação real da corrente de fuga AC RMS de 0,01mA a 40 A com resolução de 0.01 mA

Registro de dados programável com pontos de dados de 99

Alarme Alto/baixo programável

(65mm×32mm) para hastes de aterramento grandes

Especificações gerais

Função

Ensaio de resistência ao solo, Teste de resistência de loop

Fonte de energia

6V DC 4 PCS of AA Bateria alcalina

Gama de resistência

0.01-1500Ω

Resolução

0.01Ω

A maior resistência de precisão

±1%±0.01Ω

Gama de Corrente

0.00mA-40.0A

Resolução

0.05mA

A maior resistência de precisão

±2.5%±1mA

Totó

99 Sets

Limiar de alarme faixa de configuração

Resistance: 1-199Ω

Som e Luz de alarme

"Beep beep beep" Tom de alarme, alarme símbolo piscando, pressione al chave para ligar e desligar o alarme ou limiar de alarme.

Reconhecimento de sinais de interferência

 

"Beep beep beep" Tom, O ruído símbolo piscando

Gama de temp. de armazenamento/Humidade de armazenamento

-20℃-55℃;20%RH-90%RH(Por favor, totó e operar o instrumento EM SUAS GAMAS)

LCD Tela

4 Digits LCD display, Tela L×W: 47mm×28.5mm

Dimensão pinça

65mm×32mm

Pinça Abertura medida

32mm

Peso

1160g (COM baterias)

Dimensão Pinça

L×W×T: 285mm×85mm×56mm

Nível de proteção

Dual isolamento

Característica estrutural

pinça CT

Shifting

Automatic shifting

Campo magnético externo

<40A/m

Campo elétrico externo

<1V/m

Tempo de medição única

0.5 second

A medição Da resistência, frequência

>1KHz

Corrente medida de frequência

50/60Hz Medição automática

Indicação de bateria fraca

Bateria fraca símbolo Mostra Quando a bateria está Baixa, então 5.3v

Memória total indicação

MEM símbolo pisca Quando todos 99 conjuntos de memória Cheia

Sobre Gama indicação

Fora do alcance Da indicação "ol Ω", "l0.01" Ou "ol"

Auto poder fora

5 minutos depois do boot

O consumo de Energia

Max 50mA Na inicialização ou normalmente, trabalhar, trabalhar continuamente por 30 Horas

RS232 interface (opcional)

OS dados armazenados no aparelho são enviadas para o computador através de UMA interface RS232 e FIO de dados, Gerar relatório de arquivos

Disposições EM matéria de segurança

IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(150V)

Acessórios

Inclui: Contador: 1 piece, Loop de teste de resistência: 1 Piece, Mala: 1 Piece

GUIA DE SELEÇÃO

Medidores de resistência de terra

Clique em "blue", marcado para as specificaiton número de modelo.

ModelRange
Resolution
clamp sizeRS232Data StorgeAudible and visible alarm 

Othe

r

MEWOI3000B+

MEWOI3000B+_副本.jpg

0.01Ω-200Ω    0.01Ω65mm×32mmoptional 
99sets

MEWOI3100B+

MEWOI3100B+官网主图_副本_副本.jpg

ø32mm

MEWOI3000+

MEWOI3000B+_副本.jpg

0.01Ω-1200Ω   0.01Ω65mm×32mmoptional 99sets

MEWOI3100+

MEWOI3100B+官网主图_副本_副本.jpg

ø32mm

MEWOI3000D+

MEWOI3000B+_副本.jpg

0.01Ω-1200Ω 

0.00-20.00A  

0.01Ω,0.05mA  65mm×32mmoptional 99sets

MEWOI3100D+

MEWOI3100B+官网主图_副本_副本.jpg

ø32mm

MEWOI3200

MEWOI-clamp meter|earth ground resistance tester|pinza|接地电阻|curent sensor probe|电流传感器

0.01Ω-1500Ω 

0.00-40.00A  

0.01Ω,0.05mA  65mm×32mm99setsRechargable Batteries

MEWOI3800C

MEWOI3800C_副本80.jpg

0.01Ω-200Ω    0.01Ω60mm*30mmAppoint with RS485 communication interface, provide standard MODBUS-RTU communication protocol×

MEWOI3800D

MEWOI3800D_副本80.jpg

0.01Ω-200Ω  0.01Ω60mm*30mm×
LCD display,warning function.
MEWOI3800LCMEWOI3800LC.80.jpg0.01Ω-200Ω    0.01Ω

Split  Type

56mm×26mm

Wired network: RS232,RS485 standard communication protocol

Wireless network: RS232、RS485、GSM communication protocol

×

MEWOI3800LDMEWOI3800LD.80.jpg0.01Ω-200Ω  0.01Ω

Split Type

56mm×26mm

×
LCD display,warning function.

MEWOI4000

MEWOI4000C_副本.jpg

0.01Ω~2000Ω;

 0~600V

0.01Ω,1V
400sets
2/3-wires measurement of earth resistance/voltage

MEWOI4000D

MEWOI4000D-earth-resistance-tester.80.png

0.01Ω~2000Ω;

 0~600V

0.01Ω,1V
400sets
2/3-wires measurement of earth resistance/voltage

MEWOI4000C

MEWOI4000C_副本.jpg

earth resistance:0.01Ω~30.00KΩ;

soil resistivity:0.01Ωm~9000KΩm;

 0~600V

0.01Ω,0.01Ωm,1V
300sets
2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage

MEWOI4200D

MEWOI4200D-grounding-resistance-tester.80.png

earth resistance:0.01Ω~30.00KΩ;

soil resistivity:0.01Ωm~9000KΩm;

 0~600V

0.01Ω,0.01Ωm,1V
300sets
2/3/4-wires measurement of earth resistance,soil resistivity,and earth voltage

MEWOI4200

MEWOI4200-1_副本80.jpg

earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A; 

soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω

0.01Ω,0.01Ωm,0.01A,0.1Vø68mm2000sets
2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function.

MEWOI4300D

MEWOI4300D.01_80.png

earth resistance:0.01Ω~30.00KΩ;AC Leakage current: 0.00mA~600A; 

soil resistivity:0.01Ωm~9000KΩm;Earth Voltage:0.0~100.0V,dual clamp: 0.01Ω-100Ω

0.01Ω,0.01Ωm,0.01A,0.1Vø68mm2000sets
2/3/4-wires,selection & dual clamp method to measure the earth resistance,soil resistivity,earth voltage,AC voltage,AC leakage current,warning function.


Technical Specification

Function

Ground resistance test, Loop resistance test

Power Supply

6VDC 4 PCS of AA Alkaline batteries(Rechargable)

Resistance Range

0.01-1500Ω

Resistance Resolution

0.001Ω

Highest Resistance Accuracy

±1%±0.01Ω

Current Range

0.00mA-40.0A

Current Resolution

0.05mA

Highest Current Accuracy

±2.5%±1mA

USB Interface1.5M USB Cable

Data memory

999 Sets

Working Current≤50mA
Start self inspection time≤1s
Clock Functiondisplay hour,minute

Alarm Threshold Setting Range

Resistance: 0-1500Ω,Current: 1-9999A

Alarm Sound and Light

“Beep-beep-beep” alarm tone, Alarm Symbol Flashing, Press AL key to turn on, turn off Alarm or set Alarm Threshold.

Interference Signal Recognition

 “Beep-beep-beep” tone, NOISE symbol blinking

Auto Power OffThe instrument does not operate for 5 minutes, then flashes for 30seconds, and then automatically shuts down.

Working Temperature and Humidity

-20℃-55℃;20%RH-90%RH(Please storge and Operate the instrument at its ranges)

LCD Screen

4 Digits LCD display, Screen L×W: 47mm×28.5mm

Clamp Size

65mm×32mm

Clamp Opening Extent

32mm

Tester Weight

1160g (With batteries)

Clamp Dimension

L×W×T: 285mm×85mm×56mm

Protection Level

Dual Insulation

Structural Feature

Clamp CT

Shifting

Automatic shifting

External magnetic field

<40A/m

External electrical field

<1V/m

Single measurement time

0.5 second

Resistance measurement frequency

>1KHz

Measured current frequency

50/60Hz Automatic measurement

Low Battery Indication

Low battery symbol displays when battery is lower then 5.3V

Memory Full Indication

MEM symbol blinks when all 999 sets memory is full

Over Range Indication

Out of range indication “OLΩ”, “L0.01” or “OL A”

Power Consumption

Max 50mA either in booting up or normally working, Continuously working for 30 hours

USB interface

The data stored in the meter are uploaded to the computer through USB interface and data wire, Then generate report files

Safety Provisions

IEC1010-1, IEC1010-2-032, Pollution level 2, CAT Ⅲ(150V)

Accessories

Meter: 1 piece, Test ring: 1 Piece, Meter Suitcase: 1 Piece

Meter: 1 piece, Test ring: 1 Piece, Meter Suitcase: 1 Piece

Telephone
Product Center
Aftersales
QQ