INTRODUCTION
Click to download: MEWOI9000G Color Page
Click to download: MEWOI9000G.MEWOI9000GB Flexible Current/Leakage Monitoring Recorder User Manual
Click to download: Selection Map
MEWOI9000G flexible high current clamp / logger is specially designed for field-line testing, monitoring, recording AC leakage current and Large current, It consists of host, flexible current clamps, monitoring software, communication lines and other components. Widely used in electric power, telecommunications, meteorology, railroad, oilfield, construction, measurement, research and teaching departments, industrial and mining enterprises and other fields. Particularly suitable for cable-intensive places, the wall transformer core grounding current test, thick wire cable test, relay protection , frequency conversion, semiconductor switches, electronic power conversion equipment, arc welding and other serious signal distortion current testing industrial environments. Flexible current clamp (Rockwell coil), apply to advanced Rockwell coil (or Rogowski coil) technology, is a uniform circular coil wound on a non-ferromagnetic material, no hysteresis effect is almost zero phase error, no magnetic saturation, high linearity, strong anti-interference ability. The output signal is a differential current over time, by integrating the output voltage signal , you can restore the real input current, the current measurement range from milliamps to tens of thousands of Amps. Flexible current clamp coil is without any exposed metal conductor, non-contact measuring, safe and fast; its small size, light weight, attractive appearance, soft and flexible, adapted to the environment and the narrow cable-intensive sites; high accuracy, reliability, response frequency bandwidth, users can customize the length of the coil according to actual demand. Host embedded in English interface, suitable for engineering and technical personnel of different countries. LCD display, at a glance. While having a relatively large storage space, can store 4200 sets of data, also has an automatic time setting function storage interval, the settings ranges from 1 to 60 minutes. Monitoring software supports on-line real-time monitoring and historical inquiry, dynamic display, wave indication; has a maximum, minimum, average indication; with alarm value setting and alarm indication; historical data read, access, store, sort, generate curves, printing etc. |
TECHNICAL SPECIFICATION
Functions | Field-line testing, monitoring, recording AC leakage current and Large current |
Power source | DC6V, alkaline battery LR06 1.5V×4 |
Testing Method | By integrating the output voltage signal , you can restore the real input current |
Inner diameter | (φ300mm(Optional,Can be customized) |
Range | 0.00A-20.000KA |
Resolution | 10mA |
Accuracy | ±2%±3dgt(cable in the center of the coil,23℃±2℃) |
Coil Length | 1000mm((Can be customized)) |
Current Frequency | 50Hz~60Hz(The measured current frequency,Automatic Identification) |
LCD Display | LCD:128dots×64dots |
LCD Size | 44mm×27mm |
Host Dimension | W*L*H75mm×170mm×30mm |
Diameter | φ7.5mm(Suitable for narrow cable-intensive sites) |
Weight | Host(240g),Flexible Coil(150g) |
Electric field interference | no magnetic saturation, high linearity, strong anti-interference ability |
Position error | cable in the center of the coil,don't put the cable at the split area,error doubles or more at the split area |
Sampling Rate | 2 samples/s |
Data storage | 4200 sets (data loss does not occur after power failure or replacing the battery) |
Time Setting | Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off |
Recording Time | Continuously operate for about 100hours at the power-saving mode |
Line Voltage | Line with a voltage up to AC600V |
Overflow Display | The “OL” symbol is displayed when a measured value is beyond the measurement range |
Battery. Voltage | A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. |
Rated Power | about 5mA at the power-saving mode, maximum current consumption: 20mA |
Lead Length | 2m |
Temperature and Humidity | Working: -10℃~40℃;below 80%rh |
Storage: -10℃~60℃;below 70%rh | |
Insulation Resistance | Higher than 100MΩ, 1000V |
Safety Codes | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Host: 1 PCS, Flexible Coil: 1 PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS,Batteries:LR06:4pcs |
APPLICATION
SELECTION GUIDE 1
For Flexible Coil Leakage Current Monitoring Recorder/Logger
Click "Blue" marked MODEL NO.to view the Spec
Model No. | Range | Accuracy: | Clamp mouth | Coli Length | LCD display | Data Storage | Data upload | RS232 interface | Working Time |
MEWOI9000G | AC 0.00A~20KA(50/60Hz) | AC 0.01A | Φ300mm | 1000mm | 44mm×27mm | 4200sets | √ | √ | 100hours |
MEWOI9000GB | AC 0.00A~6000A(50/60Hz) | AC 0.01A | Φ200mm | 630mm | 44mm×27mm | 4200sets | √ | √ | 100hours |
SELECTION GUIDE 2
High Accuracy leakage current Clamp Meter/Tester
Click "Blue" marked MODEL NO.to view the spec
Model | Range | Resolution | Clamp size | Data Storge | RS232 |
φ7mm | 99sets | √ | |||
AC/DC 0.0A~1000A | 0.1A | 30mm×35mm | 99sets | √ | |
AC/DC 0mA~60A | 1mA | 25mm×30mm | 99sets | √ | |
AC 0.000mA~60.00A | 1uA | 25mm×30mm | 99sets | √ | |
DC 0.0mA~6.00A | 0.1mA | 25mm×30mm | 99sets | √ | |
AC 0.00mA~300.0A | 0.01mA | 35mm×40mm | 99sets | √ | |
AC 0mA~600A | 1mA | 35mm×40mm | 99sets | √ | |
AC 0.00mA~1200A | 0.01mA | φ68mm | 99sets | √ | |
AC 0.0A~1500A ,DC 0.0A~2000A | 0.1A | φ68mm | 99sets | √ |
TECHNICAL SPECIFICATION
Functions | Field-line testing, monitoring, recording AC leakage current and Large current |
Power source | DC6V, alkaline battery LR06 1.5V×4 |
Testing Method | By integrating the output voltage signal , you can restore the real input current |
Inner diameter | (φ300mm(Optional,Can be customized) |
Range | 0.00A-20.000KA |
Resolution | 10mA |
Accuracy | ±2%±3dgt(cable in the center of the coil,23℃±2℃) |
Coil Length | 1000mm((Can be customized)) |
Current Frequency | 50Hz~60Hz(The measured current frequency,Automatic Identification) |
LCD Display | LCD:128dots×64dots |
LCD Size | 44mm×27mm |
Host Dimension | W*L*H75mm×170mm×30mm |
Diameter | φ7.5mm(Suitable for narrow cable-intensive sites) |
Weight | Host(240g),Flexible Coil(150g) |
Electric field interference | no magnetic saturation, high linearity, strong anti-interference ability |
Position error | cable in the center of the coil,don't put the cable at the split area,error doubles or more at the split area |
Sampling Rate | 2 samples/s |
Data storage | 4200 sets (data loss does not occur after power failure or replacing the battery) |
Time Setting | Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off |
Recording Time | Continuously operate for about 100hours at the power-saving mode |
Line Voltage | Line with a voltage up to AC600V |
Overflow Display | The “OL” symbol is displayed when a measured value is beyond the measurement range |
Battery. Voltage | A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. |
Rated Power | about 5mA at the power-saving mode, maximum current consumption: 20mA |
Lead Length | 2m |
Temperature and Humidity | Working: -10℃~40℃;below 80%rh |
Storage: -10℃~60℃;below 70%rh | |
Insulation Resistance | Higher than 100MΩ, 1000V |
Safety Codes | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Host: 1 PCS, Flexible Coil: 1 PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS,Batteries:LR06:4pcs |
Host: 1 PCS, Flexible Coil: 1 PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS,Batteries:LR06:4pcs