Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
MEWOI-DS2000FB-(500A-2000A) (ACDC) 60.5mm Open-loop Hall current Sensor
The current sensor based on the Hall Effect open-loop principle can measure DC, AC, pulse and various kinds of Irregular waveform current under electrical isolation conditions.
TECHNICIAL SPECIFICATION
Click to download: MEWOI-DS2000FB-(500A-2000A) (ACDC) 60.5mm Open-loop Hall current Sensor
Model Number | MEWOI-DS2000FB-(500A-2000A) (AC/DC) | |||||
Jaw Size | φ60.5mm | |||||
Rated input Current (IPN) | 500 | 800 | 1000 | 1500 | 2000 | A |
Primary Current Measure range(IP) | 0~±1000 | 0~±1600 | 0~±2000 | 0~±2500 | 0~±2500 | A |
Rated output voltage of secondary side | 4±1% | V | ||||
Power Supply Voltage (VCC) | ±12-±15(±5%) | V | ||||
Current consumption | VC=±15V <25 | mA | ||||
Galvanic isolation (Vd) | 5KV /50Hz/1min | |||||
Linearity (εL) | <1 | %FS | ||||
Accuracy X | TA =25℃ ±1 | % | ||||
Offset Voltage V0 | TA=25℃ <±25 | mV | ||||
Hysteresis offset Current IOM | IPN→0 <±30 | mV | ||||
Offset Voltage drift VOT | IP=0 TA=-25~+85℃ <±1 | mV /℃ | ||||
Response time Tr | ≤7 | μs | ||||
Operating temperature TA | -25~+85 | ℃ | ||||
Storage temperature TS | -40~+100 | ℃ | ||||
Frequency bandwidth(-3dB) | DC-20 | KHZ | ||||
Load resistance RL | ≥10k | Ω | ||||
Weight | 430 | g |
Matters needing attention:
|
Hall Current Sensor Selection Guide
Model Number | Range | Diameter | Output | Power Supply |
50,100,200,300A | 20mm(Close Loop) | 50,100,100,150mA | DC ±12V~±15V (±5%) | |
50,100,200,300,400,500A(AC/DC) | 21mm(Open Loop) | 2.5±1.25V ( ±1%) | DC +5V (±5%) | |
50,100,200,300,400,500A(AC/DC) | 21mm(Open Loop) | 4or5,4-20 mA,0-20 mA±1% | DC ±12V~±15V (±5%) | |
50,100,200,300,400,500A(AC) | 21mm(Open Loop) | 4or5,4-20 mA,0-20 mA±1% | DC ±12V~±15V (±5%) | |
50,100,200,300,400,500A(AC/DC) | 10*20mm(Open Loop) | 2.5V±1.25V ±1% | DC +5V (±5%) | |
50,100,200,300,400,500A(AC/DC) | 10*20mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) | |
300,500,600,800,1000,1500A(AC/DC) | 37*42.5mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) | |
50,100,200,300,400,500A(AC/DC) | 21mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) | |
300,400,600,800,1000,2000A(AC/DC) | 40.5mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) | |
600,800,1000,2000,2500,3000A(AC/DC) | 80mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) | |
600,1000,2000,3000,5000A(AC/DC) | 42*400mm(Open Loop) | 4±1% | DC ±12V- ±15V (±5%) | |
1000,3000,5000,8000A,10000A(AC/DC) | 140*36mm(Open Loop) | 4±1% | DC ±15V (±5%) | |
MEWOI DS8000DKL | 10000,20000,30000,40000,60000A,80000A(AC/DC) | 120mm(Open Loop) | 4or5±1% | DC ±12V- ±15V (±5%) |
MEWOI DS4000IAX | 500,800,1000,1500,2500A,4000A(AC/DC) | 64*21mm(Open Loop) | 4±1% | DC ±15V (±5%) |
MEWOI DS1500DFA | 200,400,600,800,1000A,1500A(AC/DC) | 40*30.2mm(Open Loop) | 4±1% | DC ±15V (±5%) |
MEWOI DS20000IC | 5000,7500,10000,15000,20000A,(AC/DC) | 210*100mm(Close Loop) | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS10000IB | 2000,3000,5000,8000,10000A,(AC/DC) | 140*50mm(Close Loop) | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS6000FKF | 300,600,1000,2000,4000,6000A,(AC/DC) | φ62mm | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS5000LA | 600,1000,2000,3000,5000A,(AC/DC) | 104*36mm(Open Loop) | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS5000LAA | 500,1000,2000,3000,5000A,(AC/DC) | 102*38mm(Open Loop) | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS2500LF2 | 500,1000,1500,2000,2500A,(AC/DC) | 85*27mm(Open Loop) | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS2000K | 300,500,800,1000,2000A,(AC/DC) | 64*16mm(Open Loop) | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS2000GA | 400,500,800,1000,2000A,(AC/DC) | 51*13mm(Open Loop) | 4±1% | DC ±12V- ±15V (±5%) |
MEWOI DS2000FB | 500,800,1000,1500.2000A,(AC/DC) | φ60.5mm | 4±1% | DC ±12V- ±15V (±5%) |