INTRODUCTION
MEWOI-ZD-A Series AC/DC Hipot Testing Is The Effective And Direct Way To Test Insulation Strength For Electric Equipment.It Check Dangerous Flaws And Make Sure Electric Equipment Continuous Working.It Typically Used To Test Insulation Strength For All Kinds Of Electrical Equipment,Components Like Capacitors,Insulation Materials. The Control Unit Should Be Worked Together With Testing Transformer. There Are Three Types Of Testing Transformers For Option. AC Hipot testing is the effective and direct way to test insulation strength for electric equipments,apparatus or machines.It checks dangeous flaws which assure electric equipment continuous working.Typical applications include testing of transformers, switchgear, cables, capacitors,aerial motors platforms,hot sticks bucket bricks,vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes,gloves,hydraulics hose,instruments transformers generators. |
MAIN FEATURES
1,Various test transformers, such as oil-immersed transformer, dry transformer or SF6 gas transformer, can be configured according to user's requirements. |
2,High Voltage, Current, Low Voltage Current, Time, Four Ways of Measurement. |
3,Manual operation mode improves the safety and reliability of the product. |
4,Real-time display of high voltage voltage, high voltage current, low voltage current and time is intuitive and clear. |
5,It has the functions of zero position indication, power supply indication, work indication, timing indication, safety emergency button and so on. |
6,Perfect functions such as over-current protection, Zero-start protection, sound-light language alarm and warning, power supply protection switch, etc. |
7,A new type of time relay with a wider time range (1S~99H) |
8,The new current relay is more accurate and reliable to ensure the safety of people and equipment. |
9,The test capacity is less than 10 kVA, and a new type of engineering plastic box is adopted. |
10,Small size and light weight. It is convenient for field test to move and adapts to the bad weather of rain and snow. |
11,AC/DC display can be switched. (matching) |
12,It is equipped with cascade transformer and double high voltage transformer to realize voltage withstanding test of different voltage levels. (matching) |
13,It can also customize voltage fine-tuning function for precise regulation of boost and boost of transformer calibration system. (matching) |
GENERAL TECHNICAL SPECIFICATION
Input voltage | AC 220V or 380V |
Output voltage of control unit | AC 0-250V or 0-430V |
Output current of control unit | 0-5/10/15/50A(customized) |
Output power(Capacity) | 0-3/5/10/15/20kVA(customized) |
Output voltage of HV unit | 0-50kV/100/150/200kV(customized) |
Output current of HV unit | 0-50/100/150/200/500/1000/2000mA(customized) |
Timing | 0-9999s |
Environmental temperature | -20℃--50℃ |
Voltage accuracy | ≤ 1.5%±1digit(F.S) |
Current accuracy | ≤ 1.5%±1digit(F.S) |
Control Part Parameter
Model No. | Capacity | Input Power | Output Voltage | Weight( kg ) | |||
Phase | ( V ) | ( A ) | ( V ) | ( A ) | |||
MEWOI-ZD-A-2/220 | 2 | LN | 220 | 10 | 0-250 | 8 | 14 |
MEWOI-ZD-A-3/220 | 3 | LN | 220 | 15 | 0-250 | 12 | 16 |
MEWOI-ZD-A -5/220 | 5 | LN | 220 | 25 | 0-250 | 20 | 18 |
MEWOI-ZD-A -10/220 | 10 | LN | 220 | 50 | 0-250 | 40 | 80 |
MEWOI-ZD-A-15/400 | 15 | AB | 380 | 37.5 | 0-430 | 34.8 | 90 |
MEWOI-ZD-A-20/400 | 20 | ABN | 380 | 50 | 0-430 | 46.5 | 100 |
MEWOI-ZD-A-25/400 | 25 | ABN | 380 | 62.5 | 0-430 | 58.1 | 120 |
MEWOI-ZD-A-30/400 | 30 | ABN | 380 | 75 | 0-430 | 69.7 | 140 |
MEWOI-ZD-A-50/400 | 50 | ABN | .380 | 125 | 0-430 | 116.2 | 160 |
MEWOI-ZD-A-100/400 | 100 | ABN | 380 | 250 | 0-430 | 232.5 | 250 |
Note: 1 ,Can Customize According to Customers' Requirement。 2,When the output capacity is less than 5KA (including 5KA), the control system is divided in o box type and the others are desktop type. |
Accuracy
1,High Voltage Output Display Accuracy: FS *1.5%+2 Words |
2,Display accuracy of high voltage current output: FS *2.0%+2 words |
3,Low Voltage Current Output Display Accuracy: FS *1.5%+2 Words |
Transformer Parameters
Spec | Capacity | Low Voltage Side | High Voltage Side | High Voltage(AC/DC Transformer) | Turn Ratio | 30 mintues Temperature Rise | Impendence voltage | No-load current | Weight | |||
Voltage | Current | AC output | DC Output | |||||||||
kVA | V | A | Voltage(kV) | Current | Voltage(kV) | Current | ℃ | % | % | kg | ||
1.5/50 | 1.5 | 200 | 7.5 | 50 | 30 | 70 | 21.4 | 500 | 10 | 10 | <4 | 19.5 |
3/50 | 3 | 200 | 15 | 50 | 60 | 70 | 42.9 | 500 | 10 | 10 | <4 | 27 |
5/50 | 5 | 200 | 25 | 50 | 100 | 70 | 71.4 | 500 | 10 | 10 | <4 | 52 |
10/50 | 10 | 200 | 50 | 50 | 200 | 70 | 142.9 | 500 | 10 | 10 | <4 | 80 |
15/50 | 15 | 400 | 37.5 | 50 | 300 | 70 | 214.3 | 500 | 10 | 8 | <4 | 120 |
20/50 | 20 | 400 | 50 | 50 | 400 | 70 | 285.7 | 500 | 10 | 8 | <4 | 140 |
30/50 | 30 | 400 | 75 | 50 | 600 | 70 | 428.6 | 500 | 10 | 8 | <4 | 155 |
50/50 | 50 | 400 | 125 | 50 | 1000 | 70 | 714.3 | 500 | 10 | 8 | <4 | 184 |
10/100 | 10 | 200 | 50 | 100 | 100 | 140 | 71.4 | 1000 | 10 | 10 | <4 | 135 |
15/100 | 15 | 400 | 37.5 | 100 | 150 | 140 | 107.1 | 1000 | 10 | 8 | <4 | 150 |
20/100 | 20 | 400 | 50 | 100 | 200 | 140 | 142.9 | 1000 | 10 | 8 | <4 | 215 |
30/100 | 30 | 400 | 75 | 100 | 300 | 140 | 214.3 | 1000 | 10 | 8 | <4 | 250 |
50/100 | 50 | 400 | 125 | 100 | 500 | 140 | 357.1 | 1000 | 10 | 8 | <4 | 290 |
10/150 | 10 | 200 | 50 | 100 | 66.7 | 140 | 47.6 | 1500 | 10 | 10 | <4 | 180 |
15/150 | 15 | 400 | 37.5 | 150 | 100 | 210 | 71.4 | 1500 | 10 | 8 | <4 | 200 |
20/150 | 30 | 400 | 50 | 150 | 133.3 | 210 | 95.2 | 1500 | 10 | 8 | <4 | 220 |
30/150 | 30 | 400 | 75 | 150 | 200 | 210 | 142.9 | 1500 | 10 | 8 | <4 | 280 |
50/150 | 50 | 400 | 125 | 150 | 333.3 | 210 | 238.1 | 1500 | 10 | 8 | <4 | 340 |
Note: 1 ,Can Customize according to customers' requirement。 2,The weight of the above table takes the oil-immersed test transformer as an example. The dry test transformer and the inflatable test transformer are slightly different。 |
SELECTION GUIDE
Series | Control Part | Transformer | Rise Voltage | Rise Voltage Rate | Display | Accuracy(V) | Accuracy(A) | Measure Channels | Overvoltage Protect | OverCurrent Protect | Input(V) | Output Control(V) | Output Control(A) | Output Power (Capactity) | H/V(V) Transformer | H/V(A) Transformer |
MEWOI-ZD-P-Series | Manual | Manual | Digital | 1.5 | 2.0 | 3 | √ | H&L Voltage | AC220V (380V Optional) | AC 0-250V or 0-430V | 0-5/10 /15/50A (customized) | 0-3/5/10 /15 kVA (Customized) | 0-50/100 /150/200kV (Customized) | 0-50/100 /150/200 /500/1000 /2000mA (Customized) | ||
MEWOI-ZD-D-Series | Manual | Manual | Digital | 1.5 | 2.0 | 3 | Low Voltage | AC220V (380V Optional) | AC 0-250V or 0-430V | 0-5/10 /15/50A (customized) | 0-3/5 /10/15 /50 kVA (Customized) | 0-50/100 /150/200kV (Customized) | 0-50/100/ 150/200 /500/1000 /2000mA (Customized) | |||
Integrated | ||||||||||||||||
MEWOI-ZD-M-Series | Manual | Manual | Pointer | 2.0 | 2.5 | 2 | Low Voltage | AC220V (380V Optional) | AC 0-250V or 0-430V | 0-5/10 /15/50A (customized) | 0-3/5 /10/15 /50 kVA (Customized) | 0-50/100 /150/200kV (Customized) | 0-50/100/ 150/200 /500/1000 /2000mA (Customized) | |||
MEWOI-ZD-A-Series | Manual /Auto | 6 Files Option | LCD Screen | 1.5 | 2.0 | 4 | √ | H&L Voltage | AC220V (380V Optional) | AC 0-250V or 0-430V | 0-5/10 /15/50A (customized) | 0-3/5 /10/15 /50 kVA (Customized) | 0-50/100 /150/200kV (Customized) | 0-50/100/ 150/200 /500/1000 /2000mA (Customized) | ||