Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
MEWOI-PTM600 portable composite gas analyzer,GASES COMBUSTÍVEIS DE DETECTOR,Combustion analyzer, flue gas analyzer
Default Gases to be detected
CO | H2S | O2 |
CO2 | EX(Inflammable and Explosive Gases) | NOX |
Other Configuration Options:
1:PTM600-6(CO、H2S、O2、Ex、CO2、NOX) | 2:PTM600-3(CO、H2S、O2) | 3:PTM600-2(CO、H2S) |
4:PTM600-C5H10 | 5:PTM600-C4H8O | 6:PTM600-N2H4 |
7:PTM600-C4H10 | 8:PTM600-C6H14 | 9:PTM600-4(CO、H2S、O2、Ex) |
10:PTM600-5(CO、H2S、O2、Ex、CO2) | 11:PTM600-C2H6 | 12:PTM600-AsH3 |
13:PTM600-THF | 14:PTM600-C5H12 | 15:PTM600-Xe |
16:PTM600-N2O | 17:PTM600-HBr | 18:PTM600-Ar |
19:PTM600-O2-I | 20:PTM600-YQ(CO、CO2、NOX、SO2、O2) | 21:PTM600-NO |
22:PTM600-C2H4O | 23:PTM600-O3 | 24:PTM600-NH3 |
25:PTM600-H2 | 26:PTM600-CO | 27:PTM600-CL2 |
28:PTM600-CH2O | 29:PTM600-C3H8 | 30:PTM600-MEK |
31:PTM600-ETO | 32:PTM600-VOC | 33:PTM600-C6H6 |
34:PTM600-C7H8 | 35:PTM600-C8H10 | 36:PTM600-C8H8 |
37:PTM600-CH4 | 38:PTM600-CH4O | 39:PTM600-C2H6O |
40:PTM600-CH2O | 41:PTM600-THT | 42:PTM600-C3H8O |
43:PTM600-C2H2 | 44:PTM600-SO2F2 | 45:PTM600-CH3Br |
46:PTM600-CH4S | 47:PTM600-C2H4 | 48:PTM600-COCL2 |
49:PTM600-F2 | 50:PTM600-C4H10 | 51:PTM600-C3H3N |
52:PTM600-CS2 | 53:PTM600-N2H4 | 54:PTM600-Br2 |
55:PTM600-HF | 56:PTM600-GeH4 | 57:PTM600-SiH4 |
58:PTM600-B2H6 | 59:PTM600-He | 60:PTM600-CH4-TDLAS |
61:PTM600-N2H4 | 62:PTM600-SF6 | 63:PTM600-H2O2 |
64:PTM600-N2 | 65:PTM600-Ex | 66:PTM600-NOX |
67:PTM600-CH5N | 68:PTM600-MDK | 69:PTM600-PH3 |
70:PTM600-H2S | 71:PTM600-HCL | 72:PTM600-HCN |
73:PTM600-NF3 | 74:PTM600-C2H3CL | 75:PTM600-C3H6 |
76:PTM600-C2HCL3 |
INTRODUCTION
MEWOI-PTM600 portable composite gas analyzer can be used in: accurate detection and analysis of a variety of gas concentration and measurement of environmental temperature and humidity. PTM-600 adopted 3.5-inch high-definition color screen for real-time display, adopted the gas sensors of internationally well-known brands, and the main detection principles include: electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization, and so on. Adopted Swiss high-precision capacitive digital temperature and humidity sensors. Advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. PTM-600 is suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space; and the purity of the gas leakage and various high concentration single gases with the background gas as nitrogen gas or oxygen gas. The types for detection are more than 500 types. |
MAIN FEATURES
1,It is possible to simultaneously detect 1 ~ 6 types of gases, which can be expanded to 18 or more types of gases, and the units can be switched freely Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l. |
2,Built-in pump-suction type measurement, built-in water vapor and dust filter, fast response, and the long-distance sampling is supported The built-in water vapor and dust filter is possible to prevent the damage of sensors and instruments due to the water vapor and dust, it can be used in the high humidity, and high dust environment, and the sampling distance is more than 10 meters. |
3,Rich human-machine interface 3.5-inch high-definition color screen, display the information such as real-time concentration, alarm, time, temperature, humidity, storage, and so on; the menu interface adopted high definition simulation graphics to display the function name of each menu. |
4,Function of large-capacity data storage (capacity can be customized), multiple storage modes are supported, and remote wireless transmission function is optional configuration Standard configuration is the data storage capacity for 100, 000 entries; USB disk storage and SD card storage functions are optional configuration, real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored; it is supported to use the local host to view, and delete data, and upload the data via USB, RS232 interface or infrared communication to the computer for data analysis or printing. |
5,Various kinds of communication interfaces and printing functions Infrared communication interface, RS232 interface, USB interface automatic recognition, and the built-in or external wirelessBluetooth printer is an optional configuration. |
6,High temperature gas detection (optional) The optional high-temperature sampling and cooling filter handle or high-temperature high-humidity pretreatment system will be possible to detect the smoke gas at the temperature of 1300 ℃. The detection for the gases at other temperatures can be customized. |
7,It is possible to switch among three display modes Simultaneously display the concentrations of six types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve. |
8,Graphical display, and use the form of curve to reflect the trend of gas concentration changes in a certain period of time. |
9,Infrared remote control Infrared remote control is an optional configuration; one-key operation can be realized via the function key on the infrared remote control, such as: modification of the alarm point, density calibration, zero-point calibration, noise reduction, restore the factory settings, and other functions. |
10,Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. |
11,It is possible to set whether to display the maximum value, minimum value, average value or not. |
12,Standard USB charging port, with charging protection function, USB hot-plug supported, and the charging status instrument can work properly. |
13,10000mA high capacity rechargeable polymer battery is adopted, so it is possible to work for a long period of time. |
14,High-precision temperature and humidity measurements (optional configuration). |
15,Real-time detection or timing detection is supported; when no detection will be done, it is possible to shut down the pump so as to extend the startup time. |
16,Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes sound & light alarm, display screen visual alarm. Alarm types include: concentration alarm, under-voltage alarm, and failure alarm. |
17,Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm. |
18,Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors. |
19,Zero-point automatic tracking; long-term use will not be affected by the zero drift. |
20,Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements. |
21,Chinese and English interfaces can be selected. |
22,Broad operating temperatures: -40~+70℃, and temperature compensation is supported. |
23,Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration. |
24,Meet the requirements on the design of the intrinsically safe circuits, such as anti-static, anti-electromagnetic interference. |
25,Protection level is up to IP66, and it is possible to prevent the splash water, dust, and shock. |
TECHNICAL SPECIFICATION
Gases to be detected | Arbitrary combination of 1 ~ 6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. |
Application scenarios | All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. |
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized. |
Resolution | 0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%, 0.001% Vol |
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. |
Allowable error | ≤±2% F.S (other or higher precision levels can be customized) |
Linearity | ≤±2% |
Response time | T90≤20 seconds |
Linearity | ≤±2% |
Linearity | ≤±2% |
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment. |
Recovery time | ≤30 seconds |
Sample gas temperature | -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the maximum temperature of 1300 ℃. |
Temperature and humidity measurement | Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH |
Power supply | 3.7VDC, 5400mA×2 high capacity rechargeable polymer battery |
Display mode | 3.5-inch high-definition color screen |
Detection mode | Built-in pump-suction type measurement, and flow rate at 800 ml / min. Calibration flow rate should be greater than 800 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass |
Alarm mode | It is possible to set as sound & light alarm, turning off the alarm. |
Communication interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition |
Data storage | Standard configuration is the data storage capacity for 100, 000 entries; SD card storage and USB disk storage functions are optional configuration |
Protection level | IP66 |
Explosion-proof type | Explosion-proof type |
Explosion-proof mark | Exia II CT6 |
Exterior dimensions | 255×210×125mm(L×H×W) 420×210×125mm(L×H×W)custom-made |
Weight | 2.5Kg |
Standard accessories | Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, built-in humidity dust filter, 0.4 meter stainless steel sampling handle (1 meter of hose, with dust filter, not retractable), |
Optional items | Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter), external remote sampling pump, high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, CD-ROM (upper level computer communication software), external mini wireless infrared printer, built-in mini printer, SD card storage, USB disk storage, wireless data communications |