Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
INTRODUCTION
Click to download: MEWOI1100C User Manual
Click to download: MEWOI1100C Color Page
MEWOI1100C H/L Voltage Clamp Meter specially designed and manufactured for high precision high voltage current measurement; use the latest CT technology and integrated mask digital technology; composed of special high voltage detector, wireless receiver and high voltage insulation rods. Wireless transmission can receive the measured data by penetrating storey building barriers or 30 meters. If not use insulated rods, it can also used as high-precision low-voltage clamp meter and leakage current meter, can accurately measure the 0.00mA ~600A current or leakage current. The integrated design of clamp and lead zone of MEWOI1100C H/L Voltage Clamp Meter ensures uninterrupted year-round high precision, high reliability and high stability test. The connection rods of MEWOI1100C wireless high and low voltage clamp ammeter can be applied in high voltage line current measurement and online current measure below 69KV, also with the functions of peak value maintaining, data maintaining, data memory, etc. The special clamp ammeter can facilitate clamp to exit the tested lead by pressing or pulling back insulation bar, which is time efficient and convenient; widely used in power plant, substation, industrial and mining enterprise, inspection station, electrician maintenance department for current sensing and field working. It can also be used as high and low voltage changing ratio tester, that is, respectively test the first loop and secondary loop high and low voltage current, and then obtain the voltage change through manually calculation. Insulation rod has the characteristics of moisture resistance, high temperature resistance, impact resistance, bending resistance, high insulation and scalability, etc. |
TECHNICAL SPECIFICATION
Function | High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement |
Power Supply | DC6V alkaline dry battery(1.5V AAA×4) |
Test Mode | Clamp CT, integral approach |
Transmission Mode | Wireless transmission, the maximum distance of straight line transmission is about 30m |
Display Mode | 4 bit LCD display, with backlight function |
LCD Dimension | 47mm×28.5mm |
Meter Dimension | LWH: 68mm×245mm×40mm |
Clamp Dimension | Ф33mm |
Sampling Rate | 2 times/second |
Measurement Scope | 0.00mA~600A (50/60Hz automatic) |
Resolution | 0.01mA |
Shift | 0.00mA~600A automatic shift |
Accuracy (23℃±5℃, below 70%RH) | 0.00mA~100.0A: ±1%±5dgt |
100.0A~600.0A: ±2%±5dgt | |
Line Voltage | Below 60KV line test (with 5 insulation rods operation) |
Data Memory | 99 sets, memory process is shown by MEM , full storage is shown by blinking FULL |
PEAK value maintaining | Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function. |
Data Hold | In usual testing mode, press HOLD key to keep data, shown by “HOLD” |
Data Access | “MR” indication, can access to all data |
Overflow Display | Over-range overflow function: shown in “OL A” |
Automatic Shutdown | 15 minutes after boot |
Battery Voltage | When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement |
Meter Weight | Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery) |
Working Temperature and Humidity | -25℃~40℃; below 80%Rh |
Storage Temperature and Humidity | -10℃~60℃; below 70%Rh |
Insulation Rod Dimension | φ32mm, 1m/piece (5pieces) |
Insulation Strength | AC 100kV/rms (between the 5th insulation rod and high voltage current clamp core) |
Structure | Anti-drip type Ⅱ |
Safety Provisions | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Clamp Meter : 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 4 pieces |
MEWOI H/L Voltage Current Clamp Meter Selection Guide(Click the "Blue"Marked model No.to view the Spec)
Model No. | Product Name | AC Range | Definition | Clamp Size | Data Storge | Circuit Voltage | Other |
H/L Voltage Clamp Meter | AC 0.0mA~ 1200A | 0.0mA Automatic Shift | φ50mm | 99sets | below 60KV(operated with insulation rod,Bare wire35KV) | ||
Wireless H/L Voltage Clamp Meter | wireless(Distance:30M) | ||||||
Portable H/L Voltage Clamp Meter | |||||||
H/L Voltage Clamp Current Meter | AC 0.00mA~600A | 0.01mA | φ33mm | 99sets | below 60KV(operated with insulation rod,Bare wire35KV) | ||
Wireless H/L Voltage Clamp Current Meter | AC 0.0mA~1200A | 0.1mA | φ33mm | 99sets | below 60KV(operated with insulation rod,Bare wire35KV) | wireless(Distance:30M) | |
MEWOI1100T | Portable H/L Voltage Clamp Current Meter | AC 0.00mA~600A | 0.1mA | φ33mm | 99sets | below 10KV(operated with insulation rod,Bare wire 1KV) | |
MEWOI1200 | H/L Voltage Clamp Current Meter | AC 0.00mA~1000A(0.00mA~1600A Optional) | 0.01mA | φ68mm | 99sets | below 60KV(operated with insulation rod,Bare wire35KV) | |
Wireless H/L Voltage Clamp Current Meter | 99sets | wireless(Distance:30M) |
APPLICATION
TECHNICAL SPECIFICATION
Function | High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement |
Power Supply | DC6V alkaline dry battery(1.5V AAA×4) |
Test Mode | Clamp CT, integral approach |
Transmission Mode | Wireless transmission, the maximum distance of straight line transmission is about 30m |
Display Mode | 4 bit LCD display, with backlight function |
LCD Dimension | 47mm×28.5mm |
Meter Dimension | LWH: 68mm×245mm×40mm |
Clamp Dimension | Ф33mm |
Sampling Rate | 2 times/second |
Measurement Scope | 0.00mA~600A (50/60Hz automatic) |
Resolution | 0.01mA |
Shift | 0.00mA~600A automatic shift |
Accuracy (23℃±5℃, below 70%RH) | 0.00mA~100.0A: ±1%±5dgt |
100.0A~600.0A: ±2%±5dgt | |
Line Voltage | Below 60KV line test (with 5 insulation rods operation) |
Data Memory | 99 sets, memory process is shown by MEM , full storage is shown by blinking FULL |
PEAK value maintaining | Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function. |
Data Hold | In usual testing mode, press HOLD key to keep data, shown by “HOLD” |
Data Access | “MR” indication, can access to all data |
Overflow Display | Over-range overflow function: shown in “OL A” |
Automatic Shutdown | 15 minutes after boot |
Battery Voltage | When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement |
Meter Weight | Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery) |
Working Temperature and Humidity | -25℃~40℃; below 80%Rh |
Storage Temperature and Humidity | -10℃~60℃; below 70%Rh |
Insulation Rod Dimension | φ32mm, 1m/piece (5pieces) |
Insulation Strength | AC 100kV/rms (between the 5th insulation rod and high voltage current clamp core) |
Structure | Anti-drip type Ⅱ |
Safety Provisions | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Clamp Meter : 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 4 pieces |
Clamp Meter : 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 4 pieces