Contact Us for Quotation | Email:mewoi@mewoi.com | Whatsapp: +8618620373879 |
MEWOI-MIT01-(0A-0.1A) (DC) φ26mm highly stabilized and precise fluxgate technology based leakage current transducer/Residual current transducer
INTRODUCTION
The multi-point zero-flux technology system applied in this high-precision DC transducer combines closed-loop excitation flux control technology, self-excited flux gate technology, and multiple closed loop control technology. The combination of technologies enables zero-flux closed-loop control of excitation flux, DC flux and AC flux, and can detect high-frequency ripple by constructing a high-frequency ripple sensing channel, so that the transducer can achieve high gains and measuring accuracy over the full bandwidth. |
FEATURES
Key Technologies Features | Features |
1,Excitation closed-loop control technology | 1,Insulation measurement at primary and secondary side |
2,Self-exciting demagnetization technology | 2,Excellent linearity and accuracy |
3,Multi-point zero-flux technology | 3,Extremely low temperature drift |
4,,Temperature control compensation technology | 4,Extremely low zero drift |
5,Multi-range automatic switching technology | 5,Broad band and low response time |
6,Strong anti-electromagnetic interference Application Domain | |
Application Fields | |
1,Industry Control | 2,Medical Equipment |
3,Railway | 4,Power and power grid |
5,Test instrumentation | 6,New Energy |
SPECIFICATION
Model Number | MEWOI-MIT01-(0A-0.1A) (DC) | |
Jaw Size | φ26mm | |
Rated input Current (IPN) | 0-0.1A | A |
Primary Current Measure range(IP) | 0~±0.2A(200% IPN) | A |
Rated output voltage of secondary side | 0-±2V | V |
Power Supply Voltage (VCC) | ±15(±5%)(±14.2V-±15.8V) | V |
Current consumption | VC=±15V ≥30 | mA |
Galvanic isolation (Vd) | 5KV /50Hz/1min(Primary/Secondary) | |
Transient isolation voltage(Vw) | 50us/10KV(Primary/Secondary) | |
Creepage distance | 11 | mm |
Electrical clearance distance | 11 | |
Linearity (εL) | Max 0.2 | %FS |
Accuracy X | DC current, within measuring range ±0.2 | % |
Offset Voltage V0 | Full Temperature range <±10 | mV |
Response time Tr | ≤2 | ms |
Operating temperature TA | -40~+85 | ℃ |
Storage temperature TS | -55~+95 | ℃ |
Relative humidity | 20-80 | |
Frequency bandwidth(-3dB) | DC-100 | KHZ |
Weight | 360 | g |
Residual Current Sensor Selection Guide
Model Number | Primary Nominal Current Value | Measuring Range | Secondary Nominal Signal | Accuracy | Supply Voltage(±5%) | Aperture(mm) | Mounting |
5A | 5A | 5V | 0.02% | +15V | 26 | Panel | |
3A | 3A | 5V | 0.02% | +15V | 26 | Panel | |
1A | 1A | 5V | 0.02% | +15V | 26 | Panel | |
0.1A | 0.1A | 5V | 0.02% | +15V | 26 | Panel | |
0.01A | 0.01A | 5V | 0.02% | +15V | 26 | Panel |
Matters needing attention:
|
|
|
|
|