Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

MEWOI-FTC198-Ultrasonic Thickness meter,Ultrasonic Thickness Gauge, Sound Velocity thickness meter

1,INTRODUCTION

Used for measuring thickness and corrosion of pressure vessels,chemical equipment, boilers,oil storage tanks,etc.in industries of petroleum, shipbuilding,power station,and machine manufacturing.

2MAIN FEATURES

A. Strong transmit power and high broadband receiver sensitivity, Probes adapted to different frequencies Severely corroded rough surfaces, paints or gray cast iron can be measured.  It is applied in almost all industries.

B. Wide range of applications:Petrochemical Industry, Shipbuilding Industry, Automobile Manufacturing Industry, Power Station,Thickness and corrosion measurements of boilers, oil tanks, pipes, pipes, slabs, forgings, flanges, hulls, decks, rails and machined parts in machine manufacturing

Most materials that can transmit ultrasonic wave can be measured by this instrument.

C. Digital display, no parallax

D. Sound speed channel and sound speed display. The instrument provides 8 sound speed channels. The sound speed of each channel can be set arbitrarily.

3,MATERIAL SELECTION

Code
Material
CD01
Steel
CD02
Cast Iron
CD03
Aluminum
CD04
Red Copper
CD05
Brass
CD06
Zinc
CD07
Quartz Glass
CD08
Polyethylene
CD09
PVC
CD10
Gray Cast Iron
CD11
Nodular Cast Iron
XXXX
Sound Velocity

4,TECHNICAL SPECIFICAITON

DisplayLCD
SensorUltrasonic Probe
Measuring Range0.75-300.0mm(determined by probe)
Resolution0.1mm
Accuracy±(1%H+0.1)mm
Sound Velocity1000m/s-9999m/s
Lower Limit of Pipes
Φ15x2.0mmΦ20x3.0
Determined By Transducer
Thickness of the measured sample≥20mm(Accuracy: ±5%)
Operating
Conditions
Temperature0~40ºC
Humidity<85%RH
Power Supply4x1.5V AABattery
Dimensions150x73x32mm
Weight400g(Not Including Batteries)

5, Button instruction

POWER

Power switch.The instrument can manual turn on, turn off automatically and manually.(Waiting for measurement over 1 minute,it will automatic power off)

LIMIT:

Set upper and lower limit for warning

CHM:

choose frequency of probe

CHV:

choose velocity

>>:

Move cursor to enter data.

∧:

data plus 1/ data query

∨:

data minus 1/ data query /zero the memory

MEWOI OEM/ODM  Instruments Manufacturer

to confirm/change speed velocity

MEWOI OEM/ODM  Instruments Manufacturer

backlight switch

6,Display instruction

5M:display the frequency of probe(including 2M,5M,10M and high frequency H2M)
NO:85 display the number of record memoried(the number up to 85)
MEWOI OEM/ODM  Instruments Manufacturerlower power
MEWOI OEM/ODM  Instruments Manufacturersign of well coupled
CH:3 5900m/s: display the channel and velocity of sound,the instrument has 8 channels to set.
0.0mm: the current data of measurement

7,.Measure and operate

1,Just put the plug in the socket of main unit and press the “POWER’’key to switch on, there is displaying the last frequency of prob and velocity of sound.
2,If it is necessary,please choose proper prob and velocity of sound,“CHM”key will help to change the frequency(2M,5M,10M,H2M is avaliable).While  “CHV”key is for changing and choosing the velocity of sound. during the unit is waiting for measurement ,press the“MEWOI OEM/ODM  Instruments Manufacturer”key,then the unit step in o the velocity of sound changing status,velocity can be changed by three buttons(“》”move cursor, “∧”plus 1,“∨”minus 1).
3,Drop the couplant on the sample to be measuresed, couple the probe with the sample.The thickness is display on the screen.If taking the probe away the value wil be keep on ,but the sign of coupling will disappear.Meanwhile, the number of record memoried plus 1(the eighty-fifth record should be changed if records exceeds 85)

8,Setting upper and lower limit

The instrument have the upper and lower limit setting function,and if the measurement is above the upper limit or under the lower limit during the operation,there is buzz sound to report.
Press “LIMIT”key,the instrument step in o the upper and lower limit setting status.Meanwhile “LIMIT: L”is displaying,which indicate inputting the lower limit.Cooperating with “>>”“∨”“∧” to input the lower limit,then press “
MEWOI OEM/ODM  Instruments Manufacturer” to confirm.After this ,the “LIMIT :H”is displaying,the setting is as same as the lower limit.Thus the warning setting is over.

8.Measure the velocity of sound

If it is necessary to measure the velocity of sound,firstly,measure the standard thickness of sample by vernier caliper,the mininum thickness suggested is 20 mm.When the unit enter state of readiness,press “>>” to enter state of measurement ,the set operation is as follows:
Input the measured thickness (setting method has referenced in the 6th part),and press “
MEWOI OEM/ODM  Instruments Manufacturer” to confirm. Couple the probe with the sample, put away the probe after the signal of coupling appears, the screen appers the velocity of sound,meanwhile the current velovity of channel has been replaced by the measurement..

 9.Two point calibration

 In order to improve accuracy ,the instrument provides two point calibration function, you can choose to use it as needed,when the instrument is turn off,firstly press “MEWOI OEM/ODM  Instruments Manufacturer”,next press “POWER”, then release "POWER" key before the "ZERO" key, the instruement step in o the two point calibration state.
Display: “INPUT:L”:It prompts to input the thickness of the first point,cooperate“>>”,“∨”with“∧”to input the value,then press “MEWOI OEM/ODM  Instruments Manufacturer” to confirm.
Display: “INPUT:H”:It  prompts to input the thickness of the second  point,cooperating “>>”,“∨”with“∧”to input the value,then press  “MEWOI OEM/ODM  Instruments Manufacturer” to confirm.
Display: “CALXXX”:It prompts to sample the first point, couple the probe with the first sample,don’t take away the probe untile the sign of probe displayed.
Display: “CALXXX”:It prompt to sample the second point, couple the probe with the second sample,don’t take away the probe untile the sign of probe displayed,after few seconds the instruement finished calibration and turn in o the state of readiness.

10.Save and check thickness

The instrument provides saving and checking thickness.It can save 85 value.when measurement is finished ,the thickness saved one by one,the screen displays the number of record memoried.When it over 85 values ,the current result will cover the 85th record.
 In the state of readiness, use “∧”and“∨”to roll from top to bottom ,then the screen displays the serial number of record and the thickness value at the same time.
When the serial number is 85 , press “∧”to display the sign of  “NO : 0 ? ”which prompts that whether to zero the memory or not,press “
MEWOI OEM/ODM  Instruments Manufacturer” to zero,press any other keys to cancel.

11,Display the conversion of unit   

The instrument supplies two kinds of unit.When the instrument is in the turn off state ,firstly press “LIMIT” , then press the “POWER”key, and release "LIMIT" key before the " POWER " key, the conversion of "mm or in" finished. the result will saved until the next conversion.

12. Attention

1,The instrument provide 5mm steel board.Using the other samples to measure,you need to drop couplant . Clean sample after used to keep prob from rusting.
2,Alcoho,dilution and so on would corrod the case of instrument,especially the window.During cleaned,you just need to wipe it with a little water.
3,the surface of probe is made of propylene resin ,it is sensitive to the rough surface ,so press it softly .
4,when measured at the ordinary temperature ,the temperature of surface to be measured should not be over 60ºC , unless the probe wil be injured .  
5,take care of instrument to avoid damp environment and collision.
6,If the instrument is not used for a long time,you should take out the battery.Unless it may flow the liquid which cause damage to the instrument.

SELECTION GUIDE

Model No.TypeSurface temperature of workpieceMeasuring RangeResolutionSound velocity rangeStandard thickness filmPipe measuring lower limit

MEWOI-ST200

MEWOI-ST200-Ultrasonic Thickness Gauge.80.jpg

Universal
-10―60℃0.8—300mm0.1mm1000—9999m/s4.0mm¢20mm thickness 3.0mm (5P¢10 probe, steel),¢6mm thickness 1.5mm (10P¢4 probe, steel)

MEWOI-210

MEWOI-ST210-Ultrasonic-Thickness-Gauge.80.02.jpg

Universal(Steel Special)-10―60℃0.8—300mm0.1mm1000—9999m/s4.0mm

MEWOI-220

MEWOI-ST220-Ultrasonic Thickness Gauge.80.jpg

High temperature type-10―300℃0.8—300mm0.01mm1000—9999m/s4.0mm

MEWOI-220B

MEWOI-ST20-Ultrasonic Thickness Gauge.80.jpg

Ultra high temperature type-10―450℃0.8—300mm0.01mm1000—9999m/s4.0mm

MEWOI-230

MEWOI-ST20-Ultrasonic Thickness Gauge.80.jpg

Precision type-10―60℃0.75-300mm 0.01mm1000—9999m/s4.0mm

MEWOI-240

MEWOI-ST20-Ultrasonic Thickness Gauge.80.jpg

Precision type(With cast iron function)-10―60℃0.75-300mm (cast iron function 3-300mm)0.01mm1000—9999m/s4.0mm

MEWOI-250

MEWOI-ST20-Ultrasonic Thickness Gauge.80.jpg

Precision type(With high temperature, cast iron function)-10―450℃0.75-300mm (cast iron function 3-300mm)0.01mm1000—9999m/s4.0mm

MEWOI-ST400

MEWOI-ST400-Ultrasonic-Thickness-Gauge.80.jpg

Smart-10―60℃0.75-300mm Steel0.1mm/0.01mm1000—9999m/s4.0mm¢20mm thickness 3.0mm (5P¢10 probe, steel),¢6mm thickness 1.5mm (10P¢4 probe, steel)

MEWOI-ST400B

MEWOI-ST400B-Ultrasonic-Thickness-Gauge.80.jpg

Smart-10―60℃0.75-300mm Steel0.1mm/0.01mm1000—9999m/s4.0mm

MEWOI-ST420

MEWOI-ST420-Ultrasonic-Thickness-Gauge.80.jpg

Intelligent high temperature type-10―300℃0.75-300mm Steel0.1mm/0.01mm1000—9999m/s4.0mm

MEWOI-ST420B

MEWOI-ST420-Ultrasonic-Thickness-Gauge.80.jpg

Intelligent high temperature type-10―450℃0.75-300mm Steel0.1mm/0.01mm1000—9999m/s4.0mm

MEWOI-ST440

MEWOI-ST440-Ultrasonic Thickness Gauge.80.jpg

Intelligent cast iron-10―60℃

5.0-60mm cast iron

1.2-300mm steel
0.1mm/0.01mm1000—9999m/s4.0mm

MEWOI-ST800

MEWOI-ST800-Ultrasonic Thickness Gauge.80.jpg

Hola-10―60℃0.13-20mm steel0.01mm/0.001mm1000—9999m/s4.0mm

MEWOI-FTC198

MEWOI-FTC198.80.jpg

Universal

0~50ºC

(60-300ºC Optional)

0.75-300.0mm(determined by probe)0.1mm1000m/s-9999m/s≥20mm(Accuracy: ±5%)Φ15x2.0mmΦ20x3.0Determined By Transducer

MEWOI-UM9810

MEWOI-UM9810-Ultrasonic-Thickness-Meter.80.png

Universal

0~50ºC

(60-300ºC Optional)

1.5~200mm/0.06~8inch

0.1mm,

±(0.5%n+0.2)

×

MEWOI-9818

MEWOI-UM9818-Ultrasonic-Thickness-Gauge.80.png

Precision type

(Steel Case)

0~50ºC

(60-300ºC Optional)

0.75~400mm(45#steel,Depend on Probe)

0.01mm/0.1mm

(±(0.5%n+0.05))

1000m/s-9999m/s
Φ15x2.0mmΦ20x3.0mm Determined By Transducer

MEWOI-KT260

MEWOI-KT260-Ultrasonic-Thickness-Gauge.80.png

Universal-10―60℃0.75~600mm (0.03~11.8inch) depends on probe

0.01mm/0.1mm

(±(0.5%n+0.05))

1000~9999m/s

 (0.039~0.394in/us)

±(0.5%Thickness+0.04)mmΦ15x2.0mmΦ20x3.0mm Determined By Transducer


Telephone
E-mail
After Sales
QQ