MEWOI1500D Three-Channel Wireless HV CT Ratio tester is a core technological product under the long-term strategy of professional detecting techniques research on electric power instruments developed by MEWOI, which is specific for the on-line measurement and detection for primary and secondary current, transformation ratio, error, phase (group) angle difference, polarity, phase sequence, and leaker in the high & low voltage current transformer and the voltage transformers in distribution system under 70KV (such as 10kV or 35kV ), and is composed of high voltage detector, three-channel low-voltage secondary current clamps, principal machine, high-voltage insulating rods, monitoring software, communication link, etc. it adopts the wireless transmission signal that is capable of penetrating wall obstacles with a direct-line transmission distance of about30m. MEWOI1500D tester is widely applicable to the current detection, abstracting-proof of electricity and field operations of transformer substations, power plants, electrical power inspection departments, industrial and mining enterprises, inspection station, and electrical maintenance departments. Current clamp: it adopts the special alloy, the latest CT technology, and the double shielding technology for a high accuracy, stability, and reliability during continuous monitoring in the entire year. Principal machine: it displays four sets of current signals, CT ratio, phase angle difference , and polarity visually in one screen simultaneously, which memory can store 1,500 sets of data; it is available to set the auto-save interval time to monitor leaker. HV detector breaks the traditional structure with an automatic opening and closing functions, it is easy to clamp or release measured wire by pressing or pulling back insulating rods, with the advantages of safety and time-saving. The lightweight insulating rod is characterized by thermo stability, moisture-proof, strong shock resistance & bending resistance high-insulation, high flexibility and so on. Monitoring Software: Functions such as real-time monitoring, historical data search, accessing, browsing, saving, and printing data available; dynamic display; MEWOI1500D ratio tester integrates the functions of single-channel wireless HV CT tester, HV & LV clamp current meter, HA current remote sensor, HA leaker tester, High accuracy clamp leaker meter, phase detector, three-channel leaker recorder ,etc. |
TECHNICAL SPECIFICATIONS
Functions | The on-line measurement and detection for primary and secondary current, transformation ratio, error, phase (group) difference, polarity, phase sequence, and leaker in the three-channel high & low voltage current transformer and the voltage transformers |
Power supply | HV Detector:DC6V alkaline batteries (1.5V AAA × 4) Principal machine: DC6V alkaline batteries (1.5V AAA × 4) 30-hour continuous operation available |
Test mode | Clamp CT,HV 1CT,LV 3 CT double- shield |
Transmission mode | High-pressure tested data transmitted through wireless network, with a linear transmission distance of20m; |
Range | HV detector 1st: 0.1mA ~1000A LV current clamp 2nd: 0.01mA ~10A |
Resolution | HV detector: 0.1mA; LV current clamp: 0.01mA |
Primary circuit test accuracy (23 ℃ ± 3 ℃, below70% RH) | 0.0mA~9.99A: ±1%±5dgt |
10.0A~49.9A: ±2%±5dgt | |
50.0A~199.9A:±3%±5dgt | |
200A~600A: ±4%±5dgt | |
601A~1000A: ±5%±5dgt | |
Secondary circuit test accuracy | 0.00mA~10A: ±1%±5dgt (three-channel being displayed in one screen) (23℃±3℃,less than 70%RH) |
CT ratio | Three kinds of transformation ratio indications : (1)convert the transformation ratio based on the adjustable basic value of5Afor secondary circuit current; (2)convert the transformation ratio based on 10kV-YY of 10kV/380V, that means 1st means the current of the line under 380V, 2nd means the secondary circuit current of CT under the 380V, and then calculate the ratio between the 10KV line and the secondary circuit; (3)the measured current ratio can be calculated by the measured CT ratio between the primary and secondary circuit) |
Reference Range | Reference range of transformation:0.00A~99.99A, the default secondary circuit current is transformed to5A; |
Range of Ratio error (F.Er) | 0.0% ~ 9.9%, the error between the measured CT ratio and the preset CT ratio |
Range ofCT ratio | 0000~9999/0.0A~9.9A |
Range of Ratioerror | 0.0%~ 9.9%, the principal machine can sound a alarm of “beep - beep – beep” if the measured value is more than the preset error. |
Phase polarity | Symbol indicated for in-phase positive polarity Symbol indicated for in-phase negative polarity |
Indication of Phase Sequence | Cursor in clockwise rotation and “Positive Phase” indicated for positive phase sequence Cursor in counterclockwise rotation and “Negative Phase” indicated for negative phase sequence |
Indication of Error | Symbol “Error” indicated if the tester can’t identify the phases, polarity, and phase sequence properly; |
Data Storage | 1500 sets of dada memory; press the Left arrow key to select data, and to save and auto-number the selected data (the good condition of data available under power-down or battery replacement) |
Automatic Recording Interval Time | From 00 minutes to 99 minutes, the tester stops automatic record if being set to 00 minutes; the principal machine doesn’t shut down automatically if being set from 01 minutes to 99 minutes. |
Sampling rate | 3 times / sec |
Shift | Full-automatic shift |
Dimensions | Principal machine:W75mm× H170mm× T30mm; HV detector: W76mm× H255mm× T31mm; LV current clamp: W70mm× H115mm× T38mm; |
Clamp Size | HV detector clamp: φ48mm LV current clamp:25mm×30mm |
Voltage | Less than 70kV voltage for line test(operation by being connected to 5 insolating rods required) |
Display Mode | LCD: 128dots × 64dots; backlight available for dark areas |
LCD Size: | 44mm ×27mm; |
Data Retention | Press the Left arrow key to retain the data ; press the Left arrow key to cancel retention if the symbol “HOLD” displays; |
Data Search | Press the MEM key and the Arrow key to search data; |
Overflow Display | Overflow available if being out of range: the symbol “OL A” displayed; |
Zero-signal indication | The symbol “---” is shown if the principal machine can’t receive the signal from the HV detector; |
Backlight Control | Available; ON / OFF means to open /close the backlight; |
Alarm prompt | The principal machine can sound an alarm of “beep - beep – beep” if the measured value is more than the preset error. and press the Right arrow key to launch or stop the alarm function; |
Auto power-off | Automatic power-off available after about 15 minutes as of starting; |
Battery voltage | The low- voltage symbol is displayed to remind user to replace the battery if the battery voltage is lower than 4.8V; |
Weight | Principal machine:240g(including batteries) HV detector:335g(including batteries) LV current clamp:150g× 3 Total weight:10kg(including instrument box and the insulating rods) |
Requirements on Interferences | No strong electromagnetic interference; no interference from 433MHz and 315MHz channel |
Operating temperature and humidity | -25℃~45℃; less than 80%Rh |
Storage temperature and humidity | -10℃~60℃; less than 70%Rh |
Insulating rod size | Outer diameter φ32mm, inner diameter φ24mm,1m/piece, 5 pieces |
Lead length ofLVcurrent clamp | 2 m / Piece |
Dielectric strength | AC100kV/rms between HV detector cover and the 5th insulating rod; the AC1000V/rms between the principal machine and theLVcurrent clamp shell between |
Structure | Anti-leak type II (HV detector) |
FIELD APPLICATION
Technical Specifications
Functions | The on-line measurement and detection for primary and secondary current, transformation ratio, error, phase (group) difference, polarity, phase sequence, and leaker in the three-channel high & low voltage current transformer and the voltage transformers |
Power supply | HV Detector:DC6V alkaline batteries (1.5V AAA × 4) Principal machine: DC6V alkaline batteries (1.5V AAA × 4) 30-hour continuous operation available |
Test mode | Clamp CT,HV 1CT,LV 3 CT double- shield |
Transmission mode | High-pressure tested data transmitted through wireless network, with a linear transmission distance of20m; |
Range | HV detector 1st: 0.1mA ~1000A LV current clamp 2nd: 0.01mA ~10A |
Resolution | HV detector: 0.1mA; LV current clamp: 0.01mA |
Primary circuit test accuracy (23 ℃ ± 3 ℃, below70% RH) | 0.0mA~9.99A: ±1%±5dgt |
10.0A~49.9A: ±2%±5dgt | |
50.0A~199.9A:±3%±5dgt | |
200A~600A: ±4%±5dgt | |
601A~1000A: ±5%±5dgt | |
Secondary circuit test accuracy | 0.00mA~10A: ±1%±5dgt (three-channel being displayed in one screen) (23℃±3℃,less than 70%RH) |
CT ratio | Three kinds of transformation ratio indications : (1)convert the transformation ratio based on the adjustable basic value of5Afor secondary circuit current; (2)convert the transformation ratio based on 10kV-YY of 10kV/380V, that means 1st means the current of the line under 380V, 2nd means the secondary circuit current of CT under the 380V, and then calculate the ratio between the 10KV line and the secondary circuit; (3)the measured current ratio can be calculated by the measured CT ratio between the primary and secondary circuit) |
Reference Range | Reference range of transformation:0.00A~99.99A, the default secondary circuit current is transformed to5A; |
Range of Ratio error (F.Er) | 0.0% ~ 9.9%, the error between the measured CT ratio and the preset CT ratio |
Range ofCT ratio | 0000~9999/0.0A~9.9A |
Range of Ratioerror | 0.0%~ 9.9%, the principal machine can sound a alarm of “beep - beep – beep” if the measured value is more than the preset error. |
Phase polarity | Symbol indicated for in-phase positive polarity Symbol indicated for in-phase negative polarity |
Indication of Phase Sequence | Cursor in clockwise rotation and “Positive Phase” indicated for positive phase sequence Cursor in counterclockwise rotation and “Negative Phase” indicated for negative phase sequence |
Indication of Error | Symbol “Error” indicated if the tester can’t identify the phases, polarity, and phase sequence properly; |
Data Storage | 1500 sets of dada memory; press the Left arrow key to select data, and to save and auto-number the selected data (the good condition of data available under power-down or battery replacement) |
Automatic Recording Interval Time | From 00 minutes to 99 minutes, the tester stops automatic record if being set to 00 minutes; the principal machine doesn’t shut down automatically if being set from 01 minutes to 99 minutes. |
Sampling rate | 3 times / sec |
Shift | Full-automatic shift |
Dimensions | Principal machine:W75mm× H170mm× T30mm; HV detector: W76mm× H255mm× T31mm; LV current clamp: W70mm× H115mm× T38mm; |
Clamp Size | HV detector clamp: φ48mm LV current clamp:25mm×30mm |
Voltage | Less than 70kV voltage for line test(operation by being connected to 5 insolating rods required) |
Display Mode | LCD: 128dots × 64dots; backlight available for dark areas |
LCD Size: | 44mm ×27mm; |
Data Retention | Press the Left arrow key to retain the data ; press the Left arrow key to cancel retention if the symbol “HOLD” displays; |
Data Search | Press the MEM key and the Arrow key to search data; |
Overflow Display | Overflow available if being out of range: the symbol “OL A” displayed; |
Zero-signal indication | The symbol “---” is shown if the principal machine can’t receive the signal from the HV detector; |
Backlight Control | Available; ON / OFF means to open /close the backlight; |
Alarm prompt | The principal machine can sound an alarm of “beep - beep – beep” if the measured value is more than the preset error. and press the Right arrow key to launch or stop the alarm function; |
Auto power-off | Automatic power-off available after about 15 minutes as of starting; |
Battery voltage | The low- voltage symbol is displayed to remind user to replace the battery if the battery voltage is lower than 4.8V; |
Weight | Principal machine:240g(including batteries) HV detector:335g(including batteries) LV current clamp:150g× 3 Total weight:10kg(including instrument box and the insulating rods) |
Requirements on Interferences | No strong electromagnetic interference; no interference from 433MHz and 315MHz channel |
Operating temperature and humidity | -25℃~45℃; less than 80%Rh |
Storage temperature and humidity | -10℃~60℃; less than 70%Rh |
Insulating rod size | Outer diameter φ32mm, inner diameter φ24mm,1m/piece, 5 pieces |
Lead length ofLVcurrent clamp | 2 m / Piece |
Dielectric strength | AC100kV/rms between HV detector cover and the 5th insulating rod; the AC1000V/rms between the principal machine and theLVcurrent clamp shell between |