MEWOI9300 Clamp on Leakage Current Monitoring Recorder
Ⅰ. INTRODUCTION
Click to download: MEWOI9300 User Manual
Click to download: MEWOI9300 Color Page
MEWOI9300 Three-Channel Leakage Current Monitoring Recorderis designed and manufactured for on-site simultaneous monitoring and recording 1-3 channel AC current or leakage current, it is composed of recorder host, current clamps, charger, monitoring software and communication cable, etc. Widely used in 380/220v power system, provide safe, accurate and convenient power instrument for power inspectors. Host adopts LCD display, three channels with the same screen display, clear at a glance, there are Chinese and English operation interface two choices, suitable for different countries of engineering and technical personnel. The recorder equipped large capacity rechargeable lithium battery, display power energy with a three-grid mode, which can continues recording up to 7 days. With the function of system clock and super storage space, it can set the monitoring and recording time on site, can store 200,000 sets of data, and has the function of setting the interval time of automatic storage, setting from 1 to 99 minutes. Monitoring software has online real-time monitoring and historical query functions, historical data reading, consulting, saving, reporting and other functions. The current clamp is made of Permalloy, and adopts CT technology and unique double layer magnetic shielding technology. It is almost unaffected by the external magnetic field, which ensures the uninterrupted monitoring long time with high accuracy, stability and reliability. |
Ⅱ. Technical Specification
Functions | online monitoring and recording 1 ~ 3 channel AC leakage current and current, used for circuit insulation fault troubleshooting, monitoring intermittent leakage fault, check the happen time of insulation fault and maintenance lines, etc. |
Power source | DC 3.7V rechargeable lithium battery(full charge about 4.2V) |
Testing Method | Clamp CT, TRMS |
Display Mode | LCD:128dots×64dots |
Current Clamp | 1-3PCS(Optional) |
Instrument Dimension | Host:78mm×165mm ×42mm ; Current clamp 030: 115mm ×70mm×33mm |
Weight | Host: 330g ; Current clamp 030: 170g |
LCD Dimension | Display field:44mm×27mm |
Current Clamp Lead Cable | 2 core shield wire, length 2M |
Sampling Rate | 2 times/second |
Data storage | 200,000 groups (Power down or replace battery will not lose the data) |
Record Period | Set the record interval time within 1 second ~ 99 minutes, 0 seconds is not automatically stored. |
Record Time | 1,Interval time 1 seconds, can continues recording 48 hours 2,Interval time 10 seconds, can continues recording 120 hours 3,Interval time 1 minute, can continues recording 168 hours |
Download Speed | 60KB/ Min |
Line Voltage | Below AC600V circuit test |
Overflow Display | Exceed measure range overflow function: "OL" symbol display |
Battery Voltage | Use 3.7V rechargeable lithium battery, power energy display with 3-grid, when the power energy is 0-grid indicate battery voltage is low, please charge in time |
Rated Power | In power save mode about 6mA, Max about 35mA |
Communication Interface | USB |
Record Time | In power save mode continues working 7days |
Working Temperature | Working:-10℃~40℃;below 80%rh |
Stored Temperature | Storage: -10℃~60℃ ;below 70%rh |
Insulation Resistance | 100MΩ or larger, 1000V |
Suitable Safety Standard | IEC1010-1, IEC1010-2-032, Pollution Class 2, CATⅢ(600V),IEC61326(EMC standard) |
Accessories | 1,Host,2,Current Clamps 1-3pcs Optional,3,USB/Charge Cable*1,4,Software CD*1,5,Handbag*1,6,Charger*1,7,User Manual |
SELECTION GUIDE 1
Clamp on Leakage Current Monitoring Recorder
Click "Blue" marked MODEL NO.to view the spec
Model | Range | Resolution | Clamp Size | Data Storge | Channels | Connection Type |
MEWOI9000 | 0.0A-500A | 0.1A | 35mm×40mm | 4200Sets | Single | Wired |
MEWOI9000C | 0.00mA-20A | 0.01mA | 25mm×30mm | 4200Sets | Single | Wired |
MEWOI9300B | 0.0A-500A | 0.1A | 35mm×40mm | 200000Sets | Three-Channels | Wired |
MEWOI9300 | 0.00mA-20A | 0.01mA | 25mm×30mm | 20000Sets | Three-Channels | Wired |
MEWOI9500-130T | 0.000mA-60.00A | 1uA | 25mm×30mm | 3000Sets | 1-8 Channels | Wireless |
MEWOI9500-140T | 0.00mA ~ 300.0A | 0.01mA | 35mm×40mm | 3000Sets | 1-8 Channels | Wireless |
MEWOI9500-168T | 0.00mA ~ 1200A | 0.01mA | φ68mm | 3000Sets | 1-8 Channels | Wireless |
Technical Specification
Functions | Measuring AC leakage current and AC current, monitoring current in real-time manner, locating insulation faults and repairing electrical lines. |
Power source | DC6V, alkaline battery LR03 1.5V×4 |
Testing Method | Clamp CT, TRMS |
Range | 0.0A-500A |
Resolution | 0.1A |
Accuracy | ±2%±5dgt |
Clamp size | 35mm×40mm |
Instrument Dimension | Tester(L×W×H): 75mm ×170mm ×30mm, Current clamp(L×W×H): 122mm ×70mm ×33mm |
Mass | Tester: 410g (battery included),Current clamp: 170g |
LCD Dimension | Display field: 44mm×27mm |
Shield Type | Type B: Double shielding |
Sampling Rate | 2 samples/s |
Data storage | 3900 sets (data loss does not occur after power failure or replacing the battery) |
Time Setting | Recording internal adjustable from 1 to 60 min, If set to 0 min, the auto-store function is turned off |
Recording Time | Continuously operate for about 10 days at the power-saving mode |
Line Voltage | Line with a voltage up to AC600V |
Overflow Display | The “OL” symbol is displayed when a measured value is beyond the measurement range |
Battery. Voltage | A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.6V to 4.8V. In this case, the measured values are still accurate. |
Rated Power | about 5mA at the power-saving mode, maximum current consumption: 20mA |
Lead Length | 2 m |
Temperature and Humidity | Working: -20℃~50℃;below 80%rh |
Storage: -20℃~50℃;below 70%rh | |
Insulation Resistance | Higher than 100MΩ, 1000V |
Safety Codes | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Tester: 1 PCS, Current clamp: 3PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS |
Tester: 1 PCS, Current clamp: 3PCS, Instrument bag: 1 PCS, RS232 Com-cable:1 PCS; Software Disk: 1 PCS