MEWOI-HM100P Current/Voltage Transformer CT PT Analyzer,Tester

MEWOI OEM/ODM Testing Instruments Manufacturer

Contact Us for QuotationEmail:mewoi@mewoi.comWhatsapp: +8618620373879

MEWOI-HM100P(HYCT100) Current/Voltage Transformer CT PT Analyzer,Tester

INTRODUCTION

Transformer Tester is new product created after widely adopt customers’ advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry.


Characteristics

1, Full-featured, not only satisfy the test requirements of various CTs (include TP class), such as the excitation characteristics (i.e., volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary burden, ratio error and phase displacement, but can also be used for the tests of various PTs, including excitation characteristics of the electromagnetic unit, ratio, polarity, secondary winding resistance, ratio error and phase displacement.
2,Automatically give CT, VT parameters, including knee point voltage / current, 10% error curve, the accuracy limit factor (ALF), instrument security factor (FS), the second time constant (Ts), remanence coefficient (Kr), saturated and unsaturated inductance etc.
3,Test meet IEC60044 GB1208 (-1) GB16847 (IEC60044-6) became etc all kinds of transformer standards, and in accordance with the transformer types and levels of automatic choose which standard test
4,Based on advanced principle of low-frequency test method that can meet the CT test on knee voltage up to 30KV.
5,Friendly interface beautiful, all Chinese graphic interface
6,The instrument can store 2000 groups of test data that won’t be lost when power off. After test ended, the data can be coped to PC by USB disk for analysis and being transformed in o WORD report.
7,Test is simple and convenient, one-click can complete tests of CT secondary resistance, excitation, ratio and olarity.
8,Easy to carry, because the weight is less than 9Kg.

CT/PT Analyzer Function and Technical Index



Usage

Class P/TP CT & VT

Output

0~100Vrms,12Arms,36A(peak value)

Voltage measurement accuracy

±0.2%

CT Ratio

Range

1~30000

accuracy

±0.2%

PT Ratio

Range

1~10000

accuracy

±0.2%

Phase

Range

±5min

accuracy

0.5min

DC resistance

Range

0~300Ω

accuracy

2%±2mΩ

Burden

Range

0~300VA

accuracy

2%±0.2VA

Power supply

AC220V±10%,50Hz

Environmental Conditions

  Operating temperature :-10οC~50οC,Humidity :≤90%

Weight and Dimensions

Dimensions:340 mm×300 mm×150mm,Weight<9kg